Kenwood TK-8180 Two-Way Radio User Manual


 
TK-8180
35
Controls
Panel Test Mode
Test mode operation features
This transceiver has a test mode.
To enter test mode,
press [A] key and turn power on. Hold [A] key until fre-
quency version appears on LCD.
Test mode can be inhib-
ited by programming. To exit test mode, switch the power
on again. The following functions are available in test mode.
Key operation
Key FNC not appears
Function Display
[S]
Shifts to Panel tuning mode
-
[A] Function on “FNC” appears
[B]
MSK 1200bps and 2400bps 2400bps : icon appears
[C] Test signaling CH up Signaling No.
[ ]/[ ]
Test frequency CH up/down
Channel No.
[ ]/[ ] Volume up/down -
[ ] Squelch on/off
[] Narrow/Wide 4k/Wide 5k Narrow : “n”,
Wide 4k : “s”,
Wide 5k : “w”
Microphone key
[PTT] Transmit -
[0] to [9] Use as the DTMF keypad. -
and [A], If a key is pressed during
[B], [C], transmission, the DTMF
[D], [#], corresponding to the key
[] that was presses is sent.
Key FNC appears
Function Display
[S] High power / Low power Low : icon appears
[A] Function off -
[B] Compander on/off On : icon appears
[C] Beat shift on/off On : icon appears
[ ]/[ ] Function off -
[ ]/[ ] Function off -
[ ] Squelch level 0 On : icon appears
[] LCD all lights LCD all point appears
Microphone key
[PTT] Transmit -
[0] to [9] and
Function off -
[A], [B], [C],
[D], [#], []
Notes :
If a [S], [A], [B], [C] key is pressed during transmission, the
DTMF corresponding to the key that was pressed is sent.
The “Wide 4k” can not use, please skip it.
LED indicator
Red LED Lights during transmission.
Green LED Lights when there is carrier.
Sub LCD indicator
“FNC” Appears at function on.
LCD display in panel test mode
Power
switch
Modular
MIC jack
Programmable
function keys
Volume
Up/Down key
Channel
Up/Down key
LCD
n1 1
Channel No.
n : Narrow
s : Wide 4k
w : Wide 5k
Signaling No.
Frequency and Signaling
The set has been adjusted for the frequencies shown in
the following table. When required, readjust them following
the adjustment procedure to obtain the frequencies you want
in actual operation.
Test frequency
CH RX (MHz) TX (MHz)
1 485.05000 485.10000
2 450.05000 450.10000
3 519.95000 519.90000
4 485.00000 485.00000
5 485.20000 485.20000
6 485.40000 485.40000
7~16 - -
ADJUSTMENT