8
5. Open the discard valve located near the quick dis-
connect in the filter cabinet.
6. The hose may now be used to pump the oil into the
shortening handling system and discarded proper-
ly.
7. Remove oil container to a secure area to prevent
accidental spillage.
8. Fill fryer vessel to “Fill Level” line with water.
9. Set thermostat and turn fryer on to bring water to a
gentle boil. Once boil has been reached, turn fryer
off.
WWAARRNNIINNGG
UNDER NO CIRCUMSTANCES SHOULD THE
FRYER AND FILTER BE LEFT UNATTENDED DUR-
ING BOIL-OUT. TRAINED PERSONNEL MUST BE
PRESENT DURING THE PROCEDURE TO PRE-
VENT BOIL OVER OR TO TURN OFF THE POWER
IF WATER DROPS BELOW HEATING TRANSFER
TUBES.
10. Dissolve 2/3 cup of Keating Sea Powder for every
five gallons of water and let soak for 1/2 hour. If
there is a large build-up of carbonized grease,
allow fryer to soak overnight.
11. While soaking, a natural fiber brush may be used
to scrub the tubes and inside walls of fryer. Pump
the water and Sea Powder into a dry suitable
receptacle and remove from cooking area. Sprinkle
Keating Klenzer liberally on tubes and sides of
fryer vessel. A non-abrasive scouring pad may be
used to remove the now softened carbonized
grease. Thoroughly rinse fryer vessel with potable
water to remove all Klenzer. Prior to refilling with
oil, wipe the inside of the fryer vessel making sure
all water and Klenzer have been removed.
DO NOT DAMAGE OR REPOSITION THERMOSTAT
PROBE AS THIS MAY AFFECT THE ACCURACY OF
THE FRYER.
CCAAUUTTIIOONN
DO NOT MIX WATER AND HOT OIL
12. Close the drain valve and disconnect the cleaning
hose.
Quick disconnect will remain hot for approximately
15 minutes.
13. Check thermostat bulb positioning (should be 1
paper thickness away from heat tube).
14. Refill the fryer with new or filtered oil.
Wait until filter drawer is cool before cleaning,
approximately 15 minutes.
15. Remove filter drawer, drain, clean and dry.
16. Prepare filter drawer and return to filter cabinet.
TO AVOID DAMAGING THE FRYER, DO NOT
POWER WASH, SPRAY OR HOSE IT DOWN WHILE
CLEANING IT.
17. Pump must be primed with oil after boil-out with
water.
Failure to lubricate pump may cause severe dam-
age to Filter System.
OPERATOR SELF HELP
Before calling for service, review this list. It may save
you both time and expense. This list includes com-
mon occurrences that are not the result of defective
workmanship or materials in this appliance.
NOTE: For a fryer with a Central, Zero-Space™ Filter,
or Safe & Easy Filter always check the rear drain oper-
ating handle before attempting to use the fryer. A safe-
ty switch prevents the fryer from operating if the handle
is not pushed in completely and latched. (See figure 3-
2)
Figure 3-2
Rear Drain Operating Handle
OCCURRENCE SOLUTION
Fryer does not Check power cord, unit
operate: plugged in?
Thermostat is in the
off position.
Check gas supply.
See figure below.
Reset high limit.