Datalogic Scanning Pegaso PDAs & Smartphones User Manual


 
Bar Code Parameters
Product Reference Guide
F-11
Standard 2 of 5
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Standard 2 of 5 symbol-
ogy.
0200 On / Off Off On Off
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0201 On / Off Off On Off
Enable
Checksum
Requires the use of checksum characters to
verify a bar code
0202 On / Off Off Off Off
Send Check-
sum
Instructs the terminal to include the checksum
in the label transmission.
0203 On / Off Off Off Off
Use 2-bar
Start/Stop
Allows the terminal to recognize labels that
are printed using only two bars for start/stop
characters.
0204 On / Off Off Off Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0220 01 - 50 01 01 06
Maximum
Label Length
This feature specifies the maximum allowable
length of a Standard 2 of 5 label. The length
includes check and data characters. Maximum
Label Length should be greater than or equal
to Minimum Label Length.
0221 01 - 50 01 50 10
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0222 01 - 04 01 02 01
User ID
Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier
is not to be
sent for the symbology.
0223
Any single
ASCII
ch
aracter
(00 = Off)
'F' 'F'
'F'
Trioptic
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Trioptic symbology. 0108 On / Off Off On Off
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0109 On / Off Off On Off
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0124 01 - 04 01 02
01
Code Parameter/ Description I.D. #
Acceptable
Input
Defaults
Min Max Factory