Datalogic Scanning Pegaso PDAs & Smartphones User Manual


 
Bar Code Parameters
Product Reference Guide
F-5
Maximum
Label Length
This feature specifies the maximum allowable
length of a Code 93 label. The length includes
check and data characters. Maximum Label
Length should be greater than or equal to Min-
imum Label Length.
0421 01 - 50 01 50 20
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0422 01 - 04 01 02 01
User ID
Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier
is not to be
sent for the symbology.
0423
Any single
ASCII
ch
aracter
(00 = Off)
'L' 'L'
'L'
Code 128
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Code 128 symbology. 0408 On / Off Off On On
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0409 On / Off Off On Off
Enable UCC/
EAN-128
Instructs the decoder to recognize UCC-128
versions of Code 128 labels and process them
differently by changing the Code ID, and
replacing each occurrence of the FNC1 char-
acter with GS ("ASCII" 29) characters.
040C On / Off Off On Off
ISBT Concat-
enation
Instructs the decoder to concatenate Code
128 labels conforming to the ISBT 128 stan-
dard.
040E On / Off Off Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0424 01 - 50 01 01 02
Maximum
Label Length
This feature specifies the maximum allowable
length of a Code 128 label. The length
includes check and data characters. Maximum
Label Length should be greater than or equal
to Minimum Label Length.
0425 01 - 50 01 50 20
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0426 01 - 04 01 02 01
User ID
Specifies the symbology identifier (if any) sent
when parameter Send Code ID (Index 0025)
is set to 3. "ASCII" code zero (null) is used to
indicate that an identifier is
not to be sent for
the symbology.
0427
Any single
ASCII
ch
aracter
(00 = Off)
'K' 'K'
'K'
Code Parameter/ Description I.D. #
Acceptable
Input
Defaults
Min Max Factory