Total Access 600 Series System Manual Section 4 User Interface Guide
61200624L1-1B © 2004 ADTRAN, Inc. 53
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > ACCESS
Sets A
CCESS
to O
N
or O
FF
to allow or block telnet access to the unit. The factory default value for this
parameter is
O
N
.
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > AUTHEN METHOD
Set up the Telnet authentication method from this menu. The choices are L
OCAL
P
ASSWORD
, R
ADIUS
,
L
OCAL
/R
ADIUS
, and
R
ADIUS
/L
OCAL
.
L
OCAL
/R
ADIUS
indicates that the unit will try Local Password
Authentication first, and if that fails, it will try Radius Authentication.
R
ADIUS
/L
OCAL
indicates that the unit
will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is
L
OCAL
P
ASSWORD
.
SYSTEM CONFIG > MANAGEMENT > TELNET PORT
Defines the TCP port number used when establishing a Telnet session. Normal Telnet port is 23. Enter a
customized port number if desired. Make certain the Telnet program you use is configured for the same
port number (if using a customized port number).
SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > USER LIST
Add Telnet users and control the Telnet access conditions through this menu.
#
Display the index number of the Telnet users. Up to four users can be configured for access to the
unit. Each user can be assigned a security level and idle time.
N
AME
The name is a text string of the user name for this session. The factory default is U
NASSIGNED
in the
N
AME
field.You must enter a username in this field (up to 15 characters) because the Telnet entry is
not activated until it is assigned a valid username. Editing the
U
NASSIGNED
default to be blank is
allowed for a single Telnet entry; duplicate usernames are not allowed. During an active Telnet
session the
N
AME
is displayed in the Telnet Information field located at the bottom of the menu
screen.
P
ASSWORD
When the authenticating method is L
OCAL
P
ASSWORD
, or L
OCAL
/R
ADIUS
, this text string is used for
the password. You can enter up to 30 characters in this field. The factory default is no entry in this
field.
I
DLE
T
IME
(
MINS
)
This sets the amount of time in minutes you can be idle before you are automatically logged off. The
factory default is
10
MINUTES
. The range is 1
TO
255
MINUTES
.
L
EVEL
This is the security level granted to the user. Table 3 on page 54 gives a brief description of each
level. The factory default is
F
ULL
.