61200624L1-1B © 2004 ADTRAN, Inc. 221
DLP-14 A.03 to A.04 Firmware Upgrade
Introduction
The Total Access line of Integrated Access Devices includes both the ATM and TDM versions of the
Total Access 6XX. Until now, the Total Access TDM units have been running firmware version A.03.xx.
Recently, A.04.xx has been released to support the TDM Total Access IADs. The development of A.04.xx
code is a significant step in the evolution of the Total Access product line, as it allows all Total Access
family members to share the same base code. This means that features and fixes are more easily
implemented and are propagated across the product line.
The two possible A.03 to A.04 upgrade paths are described in this DLP.
Prerequisite Procedures
Obtain the A.04 firmware and the A.03.92 (Transition Build) firmware from the ADTRAN website
(http://www.ADTRAN.com).
If further assistance is required, contact ADTRAN Technical Support at 1-888-4ADTRAN.
The choice of upgrade path will determine whether the unit's configuration is saved.
Since the A.03 and A.04 firmware loads are significantly different, the text configuration
files for the two revisions are also different. It is recommended that the customer save a
text configuration file for both the A.03 revision (prior to the upgrade) and for the A.04
revision (after completion of the upgrade). Refer to
DLP-9, Saving the Current
Configuration Using TFTP, DLP-11, Saving and Transferring a Current Configuration
Using XMODEM, or DLP-13, Saving and Loading Text Configuration using Terminal
Command Line, for further instructions on how to save the configuration.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
For the Total Access 6XX units, select
SERVICE/SUPPORT > TECHNICAL SUPPORT >
TOTAL ACCESS PRODUCTS > TOTAL ACCESS 600
.