Section 4 User Interface Guide Total Access 600 Series System Manual
174 © 2004 ADTRAN, Inc. 61200624L1-1B
Appendix B. RFC1483 Quick Start (IP Routing)
The Total Access 6XX allows for complete integration of voice and data delivery from one compact
platform (see Figure 10). Once you have completed the voice turn up procedure from the previous
example, adding data to the circuit requires some additional setup.
Figure 10. Application Diagram
To configure a Total Access 6XX for IP routing, you need to know the VPI and VCI values for the data
circuit on your network. You also need the IP address of the next hop router in the circuit.
Perform the following steps in order to configure the application.
Initial Setup
It is best to configure Total Access 6XX ATM applications by following the order of the top-level menus.
For example, first configure the system parameters using the
S
YSTEM
I
NFO
and S
YSTEM
C
ONFIG
menus.
Next, configure the Layer 1 parameters using the
I
NTERFACES
menu. Once the Layer 1 information is
configured, proceed to the Layer 2 setup using the
L2 P
ROTOCOL
menus. Follow the Layer 2 setup with the
data “routing” menus (either
B
RIDGE
or R
OUTER
). Finally, establish packet forwarding and blocking using
the
S
ECURITY
menus.
The following example provides step by step instructions for configuring the Total Access 6XX T1 ATM
system (
I
NTERFACES
and L2 P
ROTOCOL
) for a standard routing application. System Info and System Config
parameters should be set according to your system need. Refer to System Info on page 49 and System
Config on page 51 for more details.
1. Setting up the Interfaces
For more details on the configuration parameters discussed in this section, refer to the following pages:
Network T1 menus beginning on page 71
Ethernet menus beginning on page 81
TX RX
LINK
V.35 RX
V.35 TX
DATA
VOICE
BATT
PWR/NET