3Com 78-11069-01 Pager User Manual


 
Chapter 3 Preparing the Cisco CallManager and Octel Systems
Configuring the Octel Systems
3-14
Cisco Digital PBX Adapter 7630 Administration Guide
78-11069-01
Setting Dialing Sequence for Message Waiting Indicator
On Lucent and Octel systems, you must set the dialing sequence that is used to
enable and disable the MWI on phones connected to the Lucent system. After you
configure this setting on the Lucent and Octel systems, record the setting. You
need it when you configure the DPA 7630.
Assigning Incoming, Outgoing, and MWI Lines
On the Octel system, you must specify how each line is used, following these
guidelines:
When possible, separate the lines so that distinct lines are used for the three
types of call handling: incoming calls, outgoing calls, and MWI.
You can, however, assign a single line to process outgoing calls and MWI
commands. However, you must not have a single line supporting both
incoming call processing and MWI commands.
When using the hybrid integration mode, do not pass outgoing calls through
the DPA 7630.
Follow specific guidelines when physically connecting these lines to the
DPA 7630 (see “Connecting to the Telco Connectors” section on page 2-9).
However, you have flexibility in determining the number of lines used for each of
these tasks. For example, a company with a 144-port Octel voice mail system
using the hybrid integration mode might use the following configuration:
Line A
8 ports for incoming calls
Line B
2 ports for incoming calls
6 ports for MWIs
Line C
2 ports unused
6 ports for MWI pass through to PBX