Toshiba FT-8930 Cordless Telephone User Manual


 
21
6. Voice cannot be transmitted to other party (outgoing call).
Can the base and handset be
connected?
See 3. The base and handset
cannot be connected.
OK
NG
The 1 kHz, 9.0mV sine
waveform is applied to
MC601
+
side, can the 1 kHz
sine waveform from pin 24 of
IC603 be fed?
Check Q604 and its
peripheral circuit.
NG
Check whether there is the
1 kHz sine waveform at
pin 20 of IC603.
Check IC603 and its
peripheral circuit.
NG
OK
OK
Check whether there is the
1 kHz sine waveform at
“MOD” RF unit.
Check RT603 and its
peripheral circuit.
NG
OK
TX output signal from the
handset is detected by the
liner detector, can the 1 kHz
sine waveform be fed?
Check handset RF unit.
NG
OK
Check whether there is the
1 kHz sine waveform at pin 9
of IC3 on the base unit.
Check IC3, Q1 and their
peripheral circuit.
NG
OK
Check whether there is the
1 kHz sine waveform at pin 3
of IC1.
Check RT2, Q2 and their
peripheral circuits.
NG
OK
Check whether there is the
1 kHz sine waveform at
pin 6 of IC1.
Check IC1 and its
peripheral circuit.
NG
OK
Check whether there is the
1 kHz sine waveform at the
Q3 collector.
Check IC4, Q3 and its
peripheral circuit.
NG
OK
Check whether the 1 kHz sine
waveform from TEL-line
output is fed.
Check T1, RL1 and their
peripheral circuits.
NG
OK
Check MC601 of handset.
Check base RF unit.
NG
OK