26
–
Receiving the Emergency Call
If you are on the list as one of the recipients of the emergency call, you should read
the following instructions carefully. You should also notify all the persons you will
be calling so they know how to react when they receive the emergency call.
The control panel will call you when there are emergencies such as break-ins,
smoke, fire events, or someone at home needs assistance.
1. When the phone rings at the calling location, the person who answers the
phone will hear a message related to the emergency events, such as
“System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be
repeated several times depending on how it was programmed.
2. After the message has been repeated for
a certain number of times, the control panel
will ask for a valid password, you will hear
“Enter Password”.
3. Enter the 4-digit password to have access
to the control panel. If a valid password is
accepted, you will hear “Password Accepted”,
otherwise, you will hear “Password Failure”.
4. After entering the correct password, you
can follow the “Phone Command” instruc-
tions to perform the required tasks, such
as disarm, turn on / off devices or check the
system status etc. For further information
of how to control the system remotely,
please refer to the next section, "Remote
Operation by Telephone".
Zone 1
Sensor 1
Triggered
Enter
Password
-Arm
-Disarm
-Check status
-Control lighting etc.
-Disconnect
COMMUNICATION
–
31
–
®
ADVANCED PROGRAMMING
Follow the procedures below to program the beep / alarm setting.
1
2
[PROG]
[MPIN]
Enter Programming
mode
Enter master
password to
programming mode
3 beeps for valid password.
1 long beep for invalid
password.
[5]
Select Beep /
Alarm Setting
After [5] is entered, some zone
LEDs will flash or stay on.
This indicates whether that
zone is set to beep or alarm.
3
Set to Beep:
[1] to [5]
Set to Alarm:
[6] to [0].
Select which
zone you would
like to Beep or
Alarm.
Refer to the
diagram below to
select the appro-
priate setting.
If Alarm is set for that zone,
that zone LED will be on. If
Beep is set, the LED will
flash. You are allowed to
make multiple changes before
terminating programming
mode.
4
[PROG] when
finished.
Terminate pro-
gramming mode.
PROG LED will be off, and
you will hear 3 beeps.
Zone 1
BEEP
Button [1]
ALARM
Zone 2
Zone 3
Zone 4
Zone 5
Button [2]
Button [3]
Button [4]
Button [5]
Button [6]
Button [7]
Button [8]
Button [9]
Button [0]
Example:
If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply
press [0] at step 3.
This will change the zone 5 setting to “Alarm”.
This row :
Buttons for Beep
Zone LED : Flash
This row :
Buttons for Alarm
Zone LED : ON
Step Keys Function Description Note