Polycom 1725-36034-001 Cordless Telephone User Manual


 
SpectraLink 8002 Wireless Telephones Configuration and Administration (SIP)
80 PN: 1725-36034-001_B.doc
The table below lists the syslog messages and which level of logging
will produce them:
Message type Errors Events Full
Failed Handoff Yes Yes Yes
Successful Handoff No Yes Yes
Security Error Yes Yes Yes
Call Start/End No Yes Yes
Audio stats No No Yes (every 5 secs)
Audio error threshold exceeded Yes Yes Yes
Radio stats No No Yes (every 5 secs)
Radio error threshold exceeded Yes Yes Yes
All syslog messages will include:
Date and time (to 1/100th of second) since handset power on
(currently set to Jan-1 00:00.00)
Handset’s MAC address
Handset’s IP address
Syslog sequence number
The table below lists the additional items in each message type:
Failed Handoff
(Sent whenever the handset attempted to
handoff, but failed trying.)
Failed AP MAC
Failed AP signal strength
Current AP MAC
Current AP signal strength
Failure reason
Successful Handoff New AP MAC
New AP signal strength
Old AP MAC
Old AP signal strength
Reason for handoff
Other candidate APs:
MAC
Signal strength
Reason not used
Security Error AP MAC
AP signal strength
Security mode
Error details (mode dependent)