Polycom 1725-36034-001 Cordless Telephone User Manual


 
Programming the SIP Handset Features
PN: 1725-36034-001_B.doc 47
Proxy server commands
Use the following parameters when programming the configuration
files. See the sample configuration files following this table for more
detailed information.
Parameter Value Description Notes
PROXYn_ADDR
xxx.xxx.xxx.xxx:ppp
p
or
Proxy address. One
proxy address is
required but additional
proxy addresses may
be used to register
secondary line
appearances.
n = 1, 2, 3
xxx.xxx.xxx.xxx = IP address
pppp = port (optional, 5060 is
the default)
proxyname:pppp
proxyname = proxy server
name (DHCP only)
PROXYn_DOMAIN Domain name
Domain served by this
proxy server.
n = 1, 2, 3
DOMAIN = [example:
spectralink.com]
Can be omitted if a specific
proxy domain name is not
defined at the proxy server. If
omitted, defaults to the IP
address of the proxy server
(see above)
PROXYn_TYPE Asterisk
SER
Specify the
manufacturer of each
defined proxy server.
Used by the handset to
perform proxy-specific actions
based on known behavior for
specific proxy types. Omit this
parameter if the value is not
Asterisk or SER.
PROXYn_KEYPRESS_2
833
*enable
disable
*default (in example
file)
Controls generation of
in-stream RFC2833
formatted key press
events. Match what is
required by your PBX.
See RFC2833. See
config file example for
more information.
n = 1, 2, 3
Must be disabled for OAI.
PROXYn_KEYPRESS_I
NFO
enable
disable
Controls generation of
SIP INFO requests to
the SIP server for
keypress events.
Normally enabled.
n = 1, 2, 3
Must be enabled for OAI.
PROXYn_REREG_SEC
S
35 seconds to
3600 seconds
The requested
expiration interval in
REGISTER request
n = 1, 2, 3
If the server has a lower
maximum setting or a higher