3. Configuration Using the Web Interface
8900-A2-GB20-30 June 2004
3-9
3. Click on Apply.
Loss of Signal Seconds SNMP trap and TL1 autonomous message are sent if the
number of LOSS events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Loss of Link Seconds SNMP trap and TL1 autonomous message are sent if the
number of LOLS events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Errored Seconds SNMP trap and TL1 autonomous message are sent if the
number of ES events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Severely-Errored Seconds SNMP trap and TL1 autonomous message are sent if the
number of SES events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Unavailable Seconds SNMP trap and TL1 autonomous message are sent if the
number of UAS events in a 15-minute interval meets or
exceeds the selected value (0–900 seconds, where 0
disables the messages).
Increasing Rate SNMP rate change trap and TL1 autonomous message
are sent if the current rate is greater than or equal to the
previous rate plus this threshold (065535 kbps, where 0
disables the messages).
Decreasing Rate SNMP rate change trap and TL1 autonomous message
are sent if the current rate is less than or equal to the
previous rate minus this threshold (065535 kbps, where 0
disables the messages).
Init Failure Specify whether initialization failure generates
InitFailureTrap messages as specified in RFC 2662.
Yes - Enable Initialization Failure Trap messages.
No - Disable Initialization Failure Trap messages.
Field Description