Multi-Tech Systems MVP-130/130FXS IP Phone User Manual


 
MultiVOIP User Guide Technical Configuration (Analog/BRI)
239
Voice/Fax Parameter Definitions (cont’d) )
Field Name Values Description
Auto Disconnect
Automatic
Disconnect-
ion
-- The Automatic Disconnection
group provides four options which
can be used singly or in any
combination.
Jitter Value 1-65535
milli-
seconds
The Jitter Value defines the average
inter-arrival packet deviation (in
milliseconds) before the call is
automatically disconnected. The
default is 300 milliseconds. A higher
value means voice transmission will
be more accepting of jitter. A lower
value is less tolerant of jitter.
Inactive by default. When active,
default = 300 ms. However, value
must equal or exceed Dynamic
Minimum Jitter Value.
Call
Duration
1-65535
seconds
Call Duration defines the
maximum length of time (in
seconds) that a call remains
connected before the call is
automatically disconnected.
Inactive by default.
When active, default = 180 sec.
This may be too short for most
configurations, requiring upward
adjustment.
Consecutive
Packets Lost
1-65535 Consecutive Packets Lost defines
the number of consecutive packets
that are lost after which the call is
automatically disconnected.
Inactive by default.
When active, default = 30
Network
Discon-
nection
1 to 65535
seconds;
Default =
30 sec.
Specifies how long to wait before
disconnecting the call when IP
network connectivity with the
remote site has been lost.