Chapter 3 – Related MultiVOIP Setup Parameters
50 Multi-Tech Systems, Inc. Avaya Communication Manager Guide
DID Interface Parameter Definitions
Field Name Values Description
Interface DID-DPO Enables the customer-premises side of DID functionality
DID Options MultiVOIP’s use of DID applies only for incoming DID calls. The
Start Mode used by the MultiVOIP must match that used by the
originating telephony equipment, else DID calls cannot be
completed.
Start Modes Immediate Start,
Wink Start,
Delay Dial
For Immediate Start, the voip detects the off-hook condition initiated
by the telco central-office call and becomes ready to receive dial
digits immediately.
For Wink Start, the voip detects the off-hook condition. Then the
voip reverses battery polarity for a specified time (140-290 ms; a
“wink”) and then becomes ready to receive dial digits.
For Delay Dial, the voip detects detects the off-hook condition. Then
the voip reverses battery polarity for a specified time (reverse
polarity duration has wider acceptable range than for Wink Start)
and then becomes ready to receive dial digits.
Wink Timer
(in ms)
integer values,
in milliseconds
This is the length of the wink for Wink Start and Delay Dial signaling
modes..
Applicable only when Start Mode parameter is set to “Wink Start” or
“Delay Dial.”
Dialing Options
Inter Digit
Timer
integer values,
in seconds
This is the length of time that the MultiVOIP will wait between
digits. When the time expires, the MultiVOIP will look in the
phonebook for the number entered.
Default = 2.
Message
Waiting
Indication
-- Not applicable to DID-DPO interface.
Inter-Digit
Regeneration
Timer
integer values,
in milliseconds
This parameter is applicable when digits are dialed onto a DID-DPO
channel after the connection has been made. The length of time
between the outputting of DTMF digits.
Default = 100 ms.