Lucent Technologies 308/616 IP Phone User Manual


 
Step 6 Connect System To Wiring Runs
Connect the controller to the wiring runs. Following the numbers on your wiring run
labels, plug one end of a jumper cord into the jack panel box or wire junction (see pages
7 and 14) and the other end of the jumper cord into the appropriate station jack on the
controller.
Plug the controller power cord into the AC outlet.
Testing The System
Testing the Incoming Telephone Company Lines
Use a standard telephone with a modular cord. Plug the cord into the jacks for the
incoming telephone lines. If you can hear a dial tone, the lines are working. If you
do not hear a dial tone, contact your local telephone company.
Testing the Wiring Run
If you cannot get a dial tone on a
SPIRIT
telephone set, check the wiring by carrying
the set to the controller and plugging the modular cord into one of the “STATION”
jacks on the controller. If you get a dial tone at the controller, but not at the telephone
set location, the wiring is at fault.
Self Test
Your
SPIRIT
Communications System has self-test capabilities that you may use to
confirm that the system is installed correctly. The controller test checks that the
controller is working properly. You must perform the controller test at telephone 10. If
you hear an error tone during the self test, check to make sure that none of the
telephones are being used and that all the receivers are in place.
The telephone test, which checks that the telephone is working properly, is performed
at each telephone.
Controller Test
All telephones in the system must be idle.
At the controller, set the administration switch to ON.
At telephone 10, press INTERCOM.
Lift receiver.
Dial * 0 9 # * #
The test takes a few seconds to run. Then the results will be displayed on the indicator
lights of telephone 10.
Results
1. The right INTERCOM light and LINE 1 light should be lit. If either fail to light then
there is a defect in the 308 controller.
2. LINE 2 and LINE 3 lights should be lit. If either fails to light then there is a defect in
either the 308 controller or the 616 expansion unit if installed. Unplug the power cord,
remove the expansion unit, plug in the power cord, and run the test again. If the lights
still fail to light then the defect is in the 308 controller. Otherwise, the defect is in the
616 expansion unit.
Customer Installation Instructions
15