LG Electronics GDK-20W Telephone User Manual


 
GDK-20W DIGITAL WIRELESS KEY TELEPHONE SYSTEM
46
3.6.2 System Configuration
The GDK-20W DECT is used in single cell or multi-cell.
3.6.2.1 Before Installation
Followings are the factors that affect the quality of service for the GDK-20W DECT.
Location of base station
Number of wireless terminal users within a base station range
Obstructions between base station and wireless terminal
Coverage area
Desired quality of service
The purpose of this section is to provide you with information and explain tasks that you should complete to
ensure the best operation of the system.
The following procedure is very helpful to check the coverage region and install the base station:
1. Site survey (see the sub-clause A)
2. Judge where to place bases on plan drawing (see the sub-clause B).
3. For each base, check coverage tool (see the sub-clause C and CRS Tool Manual).
4. Plot limit line for each base station.
5. Check for shadow area.
6. Adjust base position for shadow area or add base if not possible.
7. Consider traffic 5 calls per cell add to plan.
8. Install the base station (see the 3.6.3 Hardware Installation).
9. Check with 335H GAP (except 340H GAP) handset using RSSI (displays only one base station at a
time, limit is -80 dbm: see the sub-clause D)
10. Walk with 2 handsets, monitor for voice quality and ‘OUT OF RANGE’ message.
11. If it is OK, finish it.
A. Site Survey
1.
Get building blue prints.
2. Check building material and thickness.
Note the general construction materials used in walls and doors between multi-story buildings, and
window coatings and coverings, if any. Also note any large metal objects, such as equipment, doors, and
fluorescent lamp shades.
In general, signals are attenuated to some lower degrees when they should pass through any barrier,
however, some materials such as metal attenuate much degree.
Note
a. Consider high traffic areas, such as conference rooms, cafeterias, and manufacturing floors.
b. Consider office locations and number of wireless terminal users within the site.