Emerson 708 Wireless Office Headset User Manual


 
Reference Manual
00809-0100-4708, Rev AD
September 2012
3-1
Rosemount 708
Section 3 Mounting
Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3-1
SAFETY MESSAGES Instructions and procedures in this section may require special precautions to
ensure the safety of the personnel performing the operations. Information that
potentially raises safety issues is indicated by a warning symbol ( ). Please
refer to the following safety messages before performing an operation
preceded by this symbol.
Warnings
MOUNTING 1. Locate the 708 on a section of piping as close as possible to the
equipment to be monitored. Align the waveguide of the transmitter as
shown in Figure 3-1 and Figure 3-2.
2. The mounting location should be free of foreign matter and corrosion
to ensure good contact between the piping and the waveguide.
3. Tighten each clamp to 10.2 N-m (90 in-lb). Trim the excess clamp
band material to prevent unwanted acoustic noise.
4. If commissioning the device, install the Green Power Module (see
Figure 3-3 on page 3-2).
5. Ensure that the Power Module cover is fully tightened to prevent
moisture ingress. The lip of the polymer Power Module cover should
be in contact with the surface of the polymer enclosure to ensure a
proper seal. Do not over tighten.
Failure to follow these installation guidelines could result in death or serious injury:
Only qualified personnel should perform the installation
Explosions could result in death or serious injury.
Before connecting a Field Communicator in an explosive atmosphere, make sure that
the instruments are installed in accordance with intrinsically safe field wiring practices
Verify that the operating atmosphere of the transmitter is consistent with the appropriate
hazardous locations certifications
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following conditions: This device may not cause harmful interference. This device must
accept any interference received, including interference that may cause undesired
operation.
This device must be installed to ensure a minimum antenna separation distance of 20
cm (8 in.) from all persons.