ClearOne comm 900 Telephone User Manual


 
Appendix— Serial Commands
87
CALLDUR - Call Duration
This command indicates how long a call has lasted. If no call is in session,this will report 0. At the
time of call termination, this command will automatically be sent out reporting the duration.
ARGUMENT DET
AILS
Name Type Size Values Units
Channel Channel 1 See Group And Channels
Group Group 1 17 (R)
Reserved 2 0
Duration String 8 String of format
HR:MN:SS
BINARY FORM DETAILS
COMMAND ID
:63
NUMBER OF ARGUMENTS
:3
ARGUMENT FORM
: <Channel><Group><Reserved><Duration>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE CALLDUR <Channel> <Duration>
CAMBAUD - Camera Control Baud Rate
This command selects/reports the baud rate of the camera control serial port.
ARGUMENT DETAILS
Name Type Size Values Units
Value Unsigned Integer 4 2400,9600, 19200, 38400
(Null to query in text)
BINARY FORM DET
AILS
COMMAND ID
:60
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Value>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE CAMBAUD [Value]
CAMCTRLMODE - Camera Control Port Mode
This command sets/reports the camera control port mode.
ARGUMENT DETAILS
Name Type Size Values Units
Value Unsigned Integer 4 0 = Sony
1 = Canon
(Null to Query in Text)
BINARY FORM DETAILS
COMMAND ID
:50
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Value>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE CAMCTRLMODE [Value]
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendix — Serial Commands
86
BATTERYLVL - Battery Level
This command reports the battery level on the remote. If the batteries run low,this command will
automatically be sent out reporting the low indication.
ARGUMENT DET
AILS
Name Type Size Values Units
Value Unsigned Integer 4 0 = battery level unavailable
1 = Lowest
2
3
4
5 = Highest
(Null to query in text.)
BINARY FORM DETAILS
COMMAND ID
:65
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Value>
TEXT FORM DETAILS
COMMAND FORM
DEVICE BATTERYLVL [Value]
BAUD - Baud Rate
This command selects/reports the baud rate of the serial port.
ARGU
MENT DETAILS
Name Type Size Values Units
Value Unsigned Integer 4 9600,19200, 38400,
57600,115200
(Null to query in text)
BINARY FORM DET
AILS
COMMAND ID
:2
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Value>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE BAUD [Value]
Attention
:If you are connected to the RAV unit through the serial port,you will need to reboot
the unit before the baud rate and flow control changes take place. If you are connected to the
RAV unit through the USB port, changes are made instantly.
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760