Avaya SM61 Cordless Telephone User Manual


 
MJH; Reviewed:
SPOC 8/4/2011
Solution & Interoperability Test Lab Application Notes
©2011 Avaya Inc. All Rights Reserved.
14 of 47
Sagemcom_SM61
Step
Description
9.
Route Pattern
Route pattern 1 was used for calls destined for the XMediusFAX fax server through
Session Manager. Route patterns 7 and 8 (not shown) were used for calls destined for
the other site in the reference configuration. Route pattern 1 was configured using the
parameters highlighted below.
Pattern Name: Any descriptive name.
Grp No: 1 This field is set to the trunk group number defined in Step 5.
FRL: 0 This field sets the Facility Restriction Level of the trunk. It must be set to
an appropriate level to allow authorized users to access the trunk. The level of 0 is
the least restrictive.
change route-pattern 1 Page 1 of 3
Pattern Number: 1 Pattern Name: to SM_21_31
SCCAN? n Secure SIP? n
Grp FRL NPA Pfx Hop Toll No. Inserted DCS/ IXC
No Mrk Lmt List Del Digits QSIG
Dgts Intw
1: 1 0 0 n user
2: n user
3: n user
4: n user
5: n user
6: n user
BCC VALUE TSC CA-TSC ITC BCIE Service/Feature PARM No. Numbering LAR
0 1 2 M 4 W Request Dgts Format
Subaddress
1: y y y y y n n rest lev0-pvt none
2: y y y y y n n rest none
3: y y y y y n n rest none
4: y y y y y n n rest none
5: y y y y y n n rest none
6: y y y y y n n rest none