Sagemcom_SM61
Step
Description
Trunk Group continued
On Page 3:
The Numbering Format field was set to unk-pvt. This field specifies the format
of the calling party number sent to the far-end.
The default values may be retained for the other fields.
display trunk-group 1 Page 3 of 21
TRUNK FEATURES
ACA Assignment? n Measured: none
Maintenance Tests? y
Numbering Format: unk-pvt
UUI Treatment: service-provider
Replace Restricted Numbers? n
Replace Unavailable Numbers? n
Modify Tandem Calling Number: no
Show ANSWERED BY on Display? y
7.
Private Numbering
Private Numbering defines the calling party number to be sent to the far-end. In the
example shown below, all calls originating from a 5-digit extension beginning with 5
and routed across any trunk group will be sent as a 5 digit calling number. The calling
party number is sent to the far-end in the SIP “From” header.
display private-numbering 0 Page 1 of 2
NUMBERING - PRIVATE FORMAT
Ext Ext Trk Private Total
Len Code Grp(s) Prefix Len
5 5 5 Total Administered: 1