- 5 -
Standard System Configuration
(1) Audio signal line
(2) Video signal line
(3) Power supply line
a. Entrance station (For details, see 2-1 and 2-2)
[1] Audio/video + digital name scrolling type
GH-VA + GH-DA/A + GH-NS, GH-10K
[2] Audio/video + direct selection type
GH-VA + GH-DA/A + GH-SW
[3] Audio + digital name scrolling type
GH-DA/A + GH-NS, GH-10K
[4] Audio + direct selection type
GH-DA/A + GH-SW
b. Bus control units
[5] Power supply PS-2410LC, PS-2410LD, PS-2410DIN
[6] Video Bus control unit GH-VBC
∗ GH-VBC can be used as an extension adaptor as well. To do so,
set the setting switch to "EXP." (2 units per trunk line)
Even if two GH-VBC units are used as extension adaptors
(SW: EXP), the wiring distance from the video Bus control
unit (SW: STD) to the farthest video residential station is
limited to 300 m (980').
[7] Bus control unit GH-BC
[8] Distribution terminal (junction): sold separately
c. Residential station (For details, see 2-4):
Station-to-station wiring
d. Residential station (For details, see 2-4): Homerun wiring
Do not mix station-to-station wiring and homerun wiring on a
single trunk line.
[9] 4-way video junction unit GH-4Z
[10] Color video residential station GH-1KD
[11] Audio residential station GH-1AD
[12] Black &White video residential station GH-1MD
Station-to-station wiring is not possible for GH-1MD
[13]
Color video residential station + handset (option) GH-1KD + GH-HS
e. Security Guard Station
[14] Security guard station GH-MK
1-1
Capacity
Entrance Station Maximum 5 stations
(up to 3 stations per trunk)
Residential Station Maximum 48 stations
(up to 25 stations per trunk)
Security Guard Station Maximum 2 stations
Residential stations
in the same residence
Maximum 4 stations
(up to 2 monitor stations)
4-way video junction unit Maximum 6 units per trunk