Aiphone 0207 AIC Intercom System User Manual


 
- 11 -
Mounting the Entrance Station (1)
[1] Back box
[2] Joint pipe
[3] Back box assembly dimensions
[4] Special screwdriver (enclosed with GH-BC)
1. Mounting the back box
Make a hole for the cable.
Use the joint pipe to assemble the back box.
Make sure the back box is mounted level.
Mount the camera and GH-NS module at eye-level for the
average height of an adult.
Do not mount the back box on a surface that is recessed by 15
mm (1/2") or more from the external surface of the wall.
2. Set up the modules.
For information on what modules can be used, see 2-1 and 2-2.
Up to 6 GH-SW modules can be used. If you would like to
connect 7 modules or more, please contact Aiphone.
3. Mount each module panel to the front frame.
Mount the panels from behind the front frame.
Insert the notch into the slots on both sides and slide it downward.
4. Mount each module to the mounting bracket.
Set the modules in the mounting bracket until they click in place.
5. Options
a. Rain hood GF-H
b. Surface-mount box GF-202B
c. Hooded surface-mount box GF-HB
d. 80 cm (32") connection cable GF-C
Peel off protection film on GH-NS display.
3-1
3
MOUNTING
1
2
3
4
5
a
b
295mm
(11-5/8")
W
44mm
(1-3/4")
25mm
(1")
25mm
(1")
25mm
(1")
W
200mm
(7-7/8")
44mm
(1-3/4")
15mm
(9/16")
x 1
x 2
x 3
x 4
x 5
x 6
x 7
x 8
x 9
110
245
380
515
650
785
920
1055
1190
W (mm)
4-5/16"
9-5/8"
15"
20-1/4"
25-9/16"
30-7/8"
36-1/4"
41-9/16"
46-7/8"
W (inch)GF-2B/3B
15mm
(9/16")
[4]
[2]
[3]
[1]
[2]
c
d
[1]
[1]