Getting Started and Using Masks
To align a Mask to the waveform
To align a Mask to the waveform
1 Access the Mask Test Setup dialog box and make sure the mask test is
enabled.
2 Locate the Use File Setup When Aligning option.
When aligning a mask to the waveform, these settings are used:
• Channel range and offset
• Time base range and position
• Trigger mode and level
• Mask test scaling source, position(s), and delay
You can either use the current oscilloscope settings, or you can use the standard
settings defined in the mask file.
3
If you want to use the standard settings defined in the mask file,
checkmark the
Use File Setup When Aligning option.
4 If you want to use the current oscilloscope settings, do not checkmark
this box.
5 Click the Align button to align the mask.
When aligning a
mask, you can use
the current settings
for the oscilloscope
setup, or use the
standard settings in
the mask file.