ADTRAN 604 Telephone User Manual


 
Section 5 DLP-11 Total Access 600 Series System Manual
214 © 2004 ADTRAN, Inc. 61200624L1-1B
1. Connect to the Total Access 6XX using the CRAFT (RJ-48) port on the back of the Total Access 6XX.
If you are not already connected to the unit’s rear CRAFT
interface, either with a VT100 compatible
terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a
VT100 Terminal or PC to the CRAFT Port. Connecting to the
CRAFT
interface limits the configuration
transfer procedure to
X
MODEM
only.
2. Log in to the unit.
3. Go to the S
YSTEM
U
TILITY
menu and select C
ONFIGURATION
T
RANSFER
menu; press <Enter>.
4. Set the T
RANSFER
M
ETHOD
menu to X
MODEM
.
5. Select S
AVE
C
ONFIG
R
EMOTELY
to start the transfers. Enter Y to confirm the transfer and prepare the
Total Access 6XX for the transfer download.
The following message is displayed: This will begin sending a copy of the current system
configuration.
6. Configure the VT100 terminal or terminal emulation software to R
ECEIVE
(and prompt for a filename).
7. View the C
URRENT
T
RANSFER
S
TATUS
to verify the progress of the current transfer.
8. From the terminal emulation software, begin the XMODEM transfer by using the appropriate command
sequence. For Windows HyperTerminal, select T
RANSFER
>R
ECEIVE
F
ILE
. Enter the filename (including
path) and select XMODEM as the transfer method.
If necessary, refer to the terminal emulation software documentation for help.
Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of
the Total Access 6XX will be inoperable from the
CRAFT interface. You can cancel the update at any
time within the terminal emulation software. (Please consult the documentation provided by the
terminal emulation software to determine how to do this.)
9. When the transfer has successfully completed, I
DLE
displays in the C
URRENT
T
RANSFER
S
TATUS
field
and XMODEM D
OWNLOAD
C
OMPLETE
displays in the P
REVIOUS
T
RANSFER
S
TATUS
field.
Perform the following steps in the order listed.
When specifying the filename, ensure that the saved file has a .cfg extension;
otherwise, the file may not be available for uploading into other Total Access 6XX
units.