Appendix D. RFC 1483 Quick Start (Bridging)
Initial Setup
It is best to configure Total Access 6XX ATM applications by following the order of the top-level menus.
For example, first configure the system parameters using the
S
YSTEM
I
NFO
and S
YSTEM
C
ONFIG
menus.
Next, configure the Layer 1 parameters using the
I
NTERFACES
menu. Once the Layer 1 information is
configured, proceed to the Layer 2 setup using the
L2 P
ROTOCOL
menus. Follow the Layer 2 setup with the
data “routing” menus (either
B
RIDGE
or
R
OUTER
). Finally, establish packet forwarding and blocking using
the
S
ECURITY
menus.
The following example provides step by step instructions for configuring the Total Access 6XX T1 ATM
system (
I
NTERFACES
and
L2 P
ROTOCOL
) for a standard bridging application. System Info and System
Config parameters should be set according to your system need. Refer to System Info on page 49 and
System Config on page 51 for more details.
1. Setting up the Interfaces
For more details on the configuration parameters discussed in this section, refer to the following pages:
Network T1 menus beginning on page 71
Ethernet menus beginning on page 81
T1 Interface Setup Instructions
Step Action
1
From the main menu, select I
NTERFACES
.
2
Highlight the C
ONFIG
menu for the T1 interface and press <E
NTER
>.
3
Right arrow to select F
ORMAT
and choose ESF or SF.
This format must match the format used by the other units in the network.
4
Set the L
INE
C
ODE
to B8ZS or AMI.
This line code must match the line code used by the other units in the network.
5
Set the E
QUALIZATION
or line build out. The default setting of 0
D
B is usually
sufficient.
6
Set the CSU L
PBK
option to E
NABLE
, D
ISABLE
, or D
ISABLE
A
LL
based on
whether looping to this unit from another unit will be allowed.