ADTRAN 604 Telephone User Manual


 
Section 5 DLP-6 Total Access 600 Series System Manual
200 © 2004 ADTRAN, Inc. 61200624L1-1B
1. Connect to the Total Access 6XX using either the 10/100BASET or CRAFT interface.
If you are not already connected to the unit’s CRAFT interface (either with a VT100 compatible
terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1, Connecting
a VT100 Terminal or PC to the CRAFT Port).
Alternately, if the unit is part of a management cluster connected to the local network, you may use a
PC connected to the network to Telnet into the unit. Use the procedures in DLP-3, Setting IP
Parameters, and DLP-5, Connecting to the Unit Using Telnet, to connect to the
10/100BASET
interface.
2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for more
details).
3. Go to the S
YSTEM
C
ONFIG
/M
ANAGEMENT
/T
ELNET
A
CCESS
menu, select the U
SER
L
IST
menu, and press
<Enter>.
4. Add a new user profile and password by selecting the first column (0) and pressing <I> (for insert).
5. Give the new user profile a name by selecting the N
AME
field, pressing <Enter>, and typing the user
defined name. All new Telnet entries have a I
NACTIVE
as the N
AME
. Enter a specific username to use
for Telnet login. Each Telnet entry in the list must have a unique assigned name because duplicate
names are not allowed. Refer to System Config > Management > Telnet Access > User List on page
53 for more details.
6. Personalize the password for the appropriate level by selecting the P
ASSWORD
field, pressing <Enter>,
then typing the appropriate password. You will have to type the new password again to confirm it.
Passwords for the Total Access 6XX system are case sensitive. There is no default password for a new
user (i.e., you can configure a user as blank with no password). The current password displays as a
series of asterisks (********).
7. Select the I
DLE
T
IME
field and press <Enter>. This field defines the amount of time in minutes the
session may be idle before the user is logged off. The range is 1-255 and the default value is 10.
Perform the steps below in the order listed.
Password security levels only apply to users connecting to the Total Access 6XX system
through Telnet access. All connections made through the
CRAFT
interface ALWAYS have
maximum security rights.