Aastra Telecom CM-16 Telephone User Manual


 
6 Model CM-16 User Guide
INSTALLATION
3. Plug the short 2 conductor line cord tail of the Power Adapter Assembly
into the 2616 Jack. When a working port is detected and the polarity
is correct (pin 3+ and pin 4- ), the center LED will blink and the left LED will
turn on steady. If both LEDs are not indicating as described, stop the
installation and verify the M1 port is working at the intended jack with a
2616 set. Next, verify all modular cord connections to this point are correct
and making good contact. When both LEDs are indicating properly,
continue at step 4.
4. Plug the power adapter transformer (Xfmr) into a non-switched 120V
AC outlet. The right LED will blink for about 40 seconds as the Base Unit
scans for its Handset. This indicates the radio circuit has been properly
powered. Go to step 5 to link the handset. If the right LED doesn’t blink,
verify the AC outlet is working and that the power adapter prongs fit snugly
in the outlet. Try another outlet just to be sure. Once the right
LED is blinking, continue at step 5.
5. While the Base Unit is scanning (right LED blinking), connect the battery to
the handset. Place the battery in the compartment and slide the door
closed. The handset should initialize and remain powered for a couple of
minutes, enough time to link with the Antenna Unit and allow you to place a
test call. Watch the handset display. As the handset initializes, two icons
will appear in the top left corner. The left icon is the battery symbol and the
internal bars of the icon show the remaining charge. The other important
icon that must appear is the Antenna just to the right of the battery icon.
When the Antenna icon appears, place a test call.
Figure 1 CM-16 Base Unit Connections
Base Unit
M1 PBX
2616 Jack
Non-switched
AC Outlet
6 Conductor
Line Cord
Xfer
Plug
Jack
Line Cord
Power Adapter
Assembly
Pins 1 &6 carry
power form adapte
r
Pins 3 &4 carry
M1 circuit (pin
3