SpectraLink h340 Cordless Telephone User Manual


 
SpectraLink Corporation Configuration and Administration—NetLink e340/i640 Wireless Telephone
Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation
Message Description Action
No PBX Response The handset has exceeded its retransmission
limit with no ACK response from Call Agent.
Verify that Call Agent IP address and port
are properly configured.
No Reg Domain Regulatory Domain Not Set Configure the Regulatory Domain of the
handset
No SVP IP The handset is configured for “static IP” (as
opposed to “use DHCP”) and no valid
NetLink SVP Server address has been
entered.
Enter a valid NetLink SVP server IP address
in the configuration setting or change to
“use DHCP.”
No SVP Response
yyy.yyy.yyy.yyy
y…y = SVP Server IP address
Handset has lost contact with the SVP Server.
This may be caused by bad radio reception
or a problem with the NetLink SVP Server.
The handset will keep trying to fix the
problem for 20 seconds, and the message
may clear by itself. If it does not, the
handset will restart. Report this problem to
the system administrator if it keeps
happening.
No SVP Server Handset can’t locate NetLink SVP Server IP address configuration of NetLink SVP
Server is wrong or missing.
NetLink SVP Server is not working Check error status screen on NetLink SVP
Server.
No LAN connection at the NetLink SVP Server Verify NetLink SVP Server connection to
LAN.
No SVP Server
No DNS Entry
Handset unable to perform DNS lookup for
SVP Server, server had no entry for SVP
Server
The network administrator must verify that
a proper IP address has been entered for
the SVP Server DHCP option.
No SVP Server
No DNS IP
Handset unable to perform DNS lookup for
SVP Server, no IP address for DNS server
The network administrator must verify
proper DHCP server operation.
No SW Found A required software component has not been
identified.
Check that the handset license type has a
corresponding entry in the slnk_cfg.cfg
file.
Check that the pd11mgd.bin and
pi110000.bin entries exist in under this
license type in the slnk.cfg.cfg file.
Not Installed! A required software component is missing Check that all required software files are
on the TFTP server, if over-the-air
downloading is being used. If the error
repeats, contact SpectraLink Technical
Support.
Press END Call The far end of a call has hung up. Hang up the near end.
Register to PBX The handset is attempting to register to the
PBX.
If this message persists, verify that the
handset is properly provisioned on the PBX
and that the 5220 Emulation mode is set
properly in the administrative menus.
Restart Command The Handset received a restart command
from the supported Mitel Networks VoIP
solution.
None. The Handset will automatically
restart in a few seconds.
PN: 72-1084-02-E.doc Page 57