Note:
- It’s not recommended to program 911, fire station or any emergency services
phone numbers into any of the phone memories without their approvals.
- Ensure to program a valid phone number and write down the programmed
phone number on the System Setting Information provide on the back of this
user's instructions.
- You may quit programming by pressing [PROG] button at any time.
- If no phone number is programmed, the ARM LED will continue to flash.
Testing Phone Numbers:
After you have programmed all the phone numbers, you should verify you have
programmed the phone numbers correctly. This can be done by triggering the
alarm silently by entering the duress password, so it dials to the programmed
phone numbers without sounding the alarm.
Note:
You must inform the recipients of the programmed phone numbers, so they know
what to expect when they receive the phone call from the control panel during an
emergency. These recipients should know the password to your control panel if
you expect them to have remote access of your control panel. For more informa-
tion regarding receiving the emergency call, please refer to page 23.
1. Press [Arm], you should hear beeping from the control panel.
2. Press [3838]. Beeping will stop, and the control panel will start to dial the first number.
3. The called party should receive the call. Pick up the call and say “Hello”, an
emergency message “System Panic” will be played. If the programmed phone
doesn’t ring, ensure the phone number is programmed correctly, or reprogram
this phone number again.
4. After the emergency message has been played for several times (depending on
how many times it was programmed), the called party will hear “Enter Password”.
5. Enter either the master password or secondary password. If the correct
password is accepted, you will hear “Password Accepted”, otherwise, you will
hear “Password Failure”.
6. Press [0][#] on the telephone to hang up.
7. The control panel will start to dial the next programmed phone number.
Note:
- Refer to page 23 [Receiving the Emergency Call] for more info on how to react
to an emergency call.
- The password is treated as a confirmation of the emergency message. Once a
valid password is entered, the control panel will not call that number again, it
will proceed to the next number.
- If any one of the called parties disarms the control panel, the control panel will
not continue to dial the remaining phone numbers.
- After calling all the programmed phone numbers, the control panel will be back
to the previous operation mode.
INSTALLATION
–
11
–
HOME AUTOMATION
Event Trigger
You can control up to 5 different devices not only manually, but also automatically. It is
called Event Trigger. That means when a sensor is triggered, the control panel will
transmit a signal to activate the designated control module. Applications include:
- Lights on when you open the front door
(walking into a room, lights on automatically),
this is called "Event Trigger on".
- Lights off when you open a door. (walk away
from a room, turns lights off), this is called
"Event Triggered off".
Event trigger is only applicable to the sensor(s)
and control module in the same zone. For
example, you can program control module 1 to
be on or off when zone 1 sensor(s) is triggered.
You can also program control module 2 to be
on / off when zone 2 sensor(s) is triggered.
Factory Default: This feature is disabled for
all zones at the factory.
To change the event trigger setting follow the instructions below.
Event Trigger On
Event Trigger Off
1
2
3
4
[PROG]
[MPIN]
Enter Program-
ming mode
Enter master
password to
programming
mode
3 beeps for valid
password. 1 long beep
for invalid password.
[7]
Select Event
Trigger
After [7] is entered,
some zone LEDs will be
off, on or flash. This
indicates the setting of
event trigger.
Disable Event
Trigger: [1] to
[5]
Enable Event
Trigger: [6] to
[0].
Select which
zone you would
like to enable /
disable event
trigger.
Refer to the
diagram below
to select the
appropriate
setting.
If event trigger “ON” is
enabled, that zone LED will
be on. If event trigger “OFF”
is enabled, that zone LED
will flash. If it is disabled, the
zone LED will be off. You are
allowed to make multiple
changes before terminating
programming mode.
[PROG]
when
finished.
Terminate
programming
mode.
PROG LED
will be off.
Step Keys Function Description Note
–