Philips KX-TAW848 Telephone User Manual


 
4.1 Troubleshooting
Installation Manual 113
4.1.2 Connection
Connection between the PBX and an APT:
Connection between the PBX and an SLT:
Connection between the PBX and an SLT that is polarity-sensitive:
CAUSE
The T/R is connected to the D1/D2.
SOLUTION
Use the correct cord (the
inner 2 wires are for T/R and
the outer 2 wires are for
D1/D2).
D1
T
R
D2
D1
T
R
D2
PBX
PBX
PBX
Extension
CAUSE
The T/R is connected to the D1/D2.
SOLUTION
Use the correct cord (the
inner 2 wires are for T/R).
D1
T
R
D2
T
R
Extension
CAUSE
The "T" is connected to the "R".
SOLUTION
Reverse the connections of
the T/R.
D1
T
R
D2
T
R
Extension
Can you dial
an extension?
(Continued on the next page.)
No
Ye s
If a telephone equipped
with an A-A1 relay is
connected to the PBX,
set the A-A1 relay switch
of the telephone to "OFF".