4.1 Troubleshooting
120 Installation Manual
002 System Reset Reset Button is pressed
Power failure
Main Board malfunction
Erroneous processing of
Main Board software
Software error due to external
factors
Ignore if not frequent
Press the Reset Button
Reprogram the PBX
Replace the PBX
010 AC power down AC power down
Bad connection or breaking of
AC cord
Check the power supply system
See if the AC cord is connected
properly
Check the AC cord
Replace the AC cord (be sure to turn
off the PBX when replacing)
011 DC power down AC power down
Power supply circuit (Main
Board) malfunction
Detection of over current
(short circuit on optional
service cards)
Check the power supply system
See if the AC cord is connected
properly
Check the AC cord
Replace the AC cord (be sure to turn
off the PBX when replacing)
Replace the PBX
Remove the optional service cards and
restart the PBX
012* MPR RAM
battery low
Battery out
Main Board (MPR)
malfunction
Replace the PBX
020* SD file access
error
SD Memory Card malfunction
Bad connection of SD
Memory Card
Main Board malfunction
Press the Reset Button
Reprogram the PBX
Replace the SD Memory Card
Replace the PBX
021* SD Memory Card
disconnected
SD Memory Card not
installed
Bad connection of SD
Memory Card
SD Memory Card malfunction
Main Board malfunction
022 Not enough free
space on SD card
Not enough memory space
available to save the system
data, or to upload system files
from the KX-TAW848
Maintenance Console
Delete the files whose file names start
with "$" from SD Memory Card
Note
Do not delete the "PSMPR" file; it is the
program file of the Main Board (MPR).
Error Code Error Message PROBABLE CAUSE SOLUTION