Panasonic KX-TDA50 IP Phone User Manual


 
1.4 Specifications
Installation Manual 29
Note
Devices connected to the Hybrid IP-PBX that exceed the system capacity will not function.
MEC Card Calculation
Calculate the MEC figure from the type and total number of items of equipment to be connected. If the MEC
figure exceeds 28, you need to install an MEC card. Note that you also need to connect an additional AC
adaptor in this case.
MEC Card Calculation
Calculation Example
The total MEC figure is 32. As this exceeds 28, you need to install an MEC card for this configuration.
Equipment Type MEC Figure
PT KX-T7600 series DPT/KX-T7600 series DSS
console
1
Other DPT/Other DSS console 1
APT 1
IP-PT 1
Pre-installed 4 Super Hybrid Ports 4
Extension Card
*1
*1
Only the extension cards that can support SLTs count for the MEC figures.
SLC4 4
SLC8 8
HLC4 0
PLC4 0
PLC8 0
CS (1 unit) 0
VPS (1 port) 1
Equipment Type MEC Figure
Pre-installed Super Hybrid Ports 4 ports 4
KX-T7600 series DPT 16 units 16
SLC4 2 cards 8
VPS 4 ports 4
Tota l 32