Maxon Telecom SP210 Two-Way Radio User Manual


 
Maxon SP200/210 Radio SP200/210
11. APPENDIX A – ACC-2003 ALIGNMENT BOX - Issue 1.0
Page 11-2 03/01
Select the required band and press Enter. Figure 11-2 will be displayed.
Figure 11-2 - Calibration Program Primary Screen
To dedicate the Communication Port, select Configuration and enter the relevant port number.
Selecting EEPROM loading will retrieve the current ASIC values, stored in the radio. This is used for
the alignment of the radio. This selection should not be made if the EEPROM is empty (new
EEPROM) or if the radio is in the middle of another operation.
If there is a Communications error, check the setting BEFORE turning the power on at the Interface
Box.
Press ‘ESC’ at error message and then ‘N’ to try again.
To write default values (see Default Settings) select ‘EEPROM’ Refill. This writes the default ASIC
values and the default frequencies.
To program the radio with the altered ASIC values, press F6.
Note
: If the channel shows ‘Unlock’ under the PLL status (top right) this implies that the channel does
not have a valid frequency programmed into the radio. This will also occur if the start-up sequence is
not observed, see Section 11.1.