Icom IC-F21S Two-Way Radio User Manual


 
5-1 PREPARATION
When you adjust the contents on page 5-5 or 5-6, SOFTWARE ADJUSTMENT, the optional CS-F21 ADJ ADJUSTMENT SOFTWARE
(Rev. 1.0 or later), OPC-478 CLONING CABLE and a JIG CABLE (see illustration at page 5-2) are required.
REQUIRED TEST EQUIPMENT
5 - 1
SECTION 5 ADJUSTMENT PROCEDURES
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
Digital multimeter
GRADE AND RANGE
Output voltage : 7.2 V DC
Current capacity : 5 A or more
Measuring range : 110 W
Frequency range : 300600 MHz
Impedance : 50
SWR : Less than 1.2 : 1
Frequency range : 0.1600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Frequency range : DC600 MHz
Measuring range : 0 to ±5 kHz
Input impedance : 10 M/V DC or better
EQUIPMENT
Audio generator
Attenuator
Standard signal
generator (SSG)
DC voltmeter
Oscilloscope
AC millivoltmeter
GRADE AND RANGE
Frequency range : 3003000 Hz
Output level : 1500 mV
Power attenuation : 40 or 50 dB
Capacity : 10 W or more
Frequency range : 120600 MHz
Output level : 0.1 µV32 mV
(127 to 17 dBm)
Input impedance : 50 k/V DC or better
Frequency range : DC20 MHz
Measuring range : 0.0120 V
Measuring range : 10 mV10 V
SYSTEM REQUIREMENTS
IBM PC compatible computer with an RS -232C serial port
(38400 bps or faster)
Microsoft Windows 95 or Windows 98
Intel i486DX processor or faster (Pentium 100 MHz or
faster recommended)
At least 16 MB RAM and 10 MB of hard disk space
640×480 pixel display (800×600 pixel display recommend-
ed)
ADJUSTMENT SOFTWARE INSTALLATION
q Boot up Windows.
- Quit all applications when Windows is running.
w Insert the cloning software CD-ROM into the appropriate
CD-ROM drive.
e Select Runfrom the [Start] menu.
r Type the setup program name using the full path name,
then push the [Enter] key. (For example; D:\ setup)
t Follow the prompts.
y Program group CS-F21appears in the Programsfolder
of the [Start] menu.
STARTING SOFTWARE ADJUSTMENT
q Connect IC-F21/F21S and PC with the optional OPC-478
and the JIG cable.
w Boot up Windows, and turn the transceiver power ON.
e Click the program group CS-F21 ADJ in the Programs
folder of the [Start] menu, then CS-21G ADJs window is
appeared.
r Click Connect on the CS-F21s window, then appears
IC-F21/21Ss up-to-date condition.
t Set or modify adjustment data as desired.
IBM is a registered trademark of International Bussiness
Machines Corporation in the U.S.A. and other countries.
Microsoft and Windows are registered trademarks of
Microsoft Corporation in the U.S.A. and other countries.
Screen shots produced with permission from Microsoft
Corporation. All other products or brands are registered
trademarks or trademarks of their respective holders.