Grandstream Networks DP710 Cordless Telephone User Manual


 
Firmware version 1.0.0.23 DP715/DP710 User Manual Page 10 of 52
Table 2: DEFINITIONS OF THE DP715 CONNECTORS
DC 6V
Power adapter connection.
NETWORK PORT
(RJ-45)
10/100Mbps RJ-45 port toconnect to the network.
RESET
Factory Reset button: Press for 7 seconds to reset factory default settings.
Table 3: BASIC DEFINITIONS OF THE DP715 LEDS PATTERN
LEDs
POWER LED
Indicates Power. Remains green when power is connected, and orange when handset is
connected for charging.
NETWORK
Indicates Access to the Network. Remains ON while there is Access to the Network
REGISTERED
Indicates if the SIP accounts are registered
CALL
Indicates status of active calls.
Table 4: ADVANCED DEFINITIONS OF THE DP715 LEDS PATTERN
Pattern
Number
Condition
LED
LED Behavior
LED-01
Device has normal power
POWER
GREEN ON
LED-02
Handset is placed on base with battery to charge
POWER
ORANGE ON
LED-03
Power Error: Power is removed from the device
POWER
OFF
LED-04
Power supply with improper voltage is plugged in
POWER
Blink ( 0.5s on/ 0.5s off )
LED-05
Device has normal LAN connection and has obtained an
IP address
NETWORK
ON
LED-06
Link Down
Note : This is the default state while the device is booting.
NETWORK
Blink (1s on/ 1s off).
LED-07
Link Up but DHCP error
NETWORK
Blink ( 0.25s on/ 0.25s
off )
LED-08
Link Up but PPPoE error
NETWORK
Blink ( 0.5s on/ 0.5s off )
LED-09
All configured SIP accounts are registered
REGISTERED
ON
LED-10
SIP accounts are in the process of registering
REGISTERED
Blink ( 1s on/ 1s off )
LED-11
Device is booting, application has not started.
REGISTERED
OFF
LED-12
No account is configured on DP715
REGISTERED
OFF
LED-13
Registration Error - ANY SIP account experiences
registration failure.
REGISTERED
Blink ( 0.5s on/ 0.5s off -
05s on/ 2s off )
LED-14
Call is active. Any DECT handset is in an active call with
an external line.
CALL
Blink ( 0.5s on/ 0.5s off )
LED-15
No active call.
CALL
OFF
LED-16
DECT Error
CALL
5 sequence of Blink
(0.25s on/0.25s off) + 3s
off
LED-17
VMWI
CALL
Blink (0.25s on/ 0.25s off -
0.25s on/ 0.25s off - 0.25s
on/ 0.75s off)
LED-18
Boot up
ALL
GREEN ON
LED-19
Factory reset
ALL
GREEN ( 0.25s on/0.25s
off 0.25s on/0.75s off )