Graco 262004 Telephone Accessories User Manual


 
Parts / Pièces / Piezas / Delen / Teile
52 312540E
Safety Interlock Wiring Diagram / Schéma de verrouillage /
Diagrama de cableado de interbloqueo de seguridad /
Bedradingsschema beveiligingssysteem /
Schaltplan für Sicherheitsverblockung
Maintenance / Entretien / Mantenimiento / Onderhoud / Wartung
English
122
10
121
123
120
37
ti10939a
Interval Action
DAILY Check engine oil level and fill as necessary.
Check hydraulic oil level and fill as necessary.
Check and fill the gas tank.
AFTER THE FIRST 20 HOURS OF
OPERATION
Drain engine oil and refill with clean oil.
Reference Honda Engines Owner's Manual for correct oil viscosity.
WEEKLY Remove engine air filter cover and clean or replace element. If operating in an unusu-
ally dusty environment: check filter daily and replace, if necessary.
Replacement elements can be purchased from your local HONDA dealer.
EVERY 100 HOURS OF OPERATION
Change engine oil. Reference Honda Engines Owner's Manual for correct oil viscosity.
YEARLY OR 500 HOURS Replace hydraulic oil and filter element. Use Mobil 1 (15W-50) synthetic oil and
Graco filter 245342.
Hydraulic Oil Replacement Procedure:
1. Remove filter and allow oil reservoir to drain from filter base.
2. Install new filter. Fill oil reservoir to top of baffle with Mobil 1 (15W-50).
3. Open drive wheel release. Start engine and run at low rpm for 3 minutes.
4. Close drive wheel release. Check oil level and top off to top of baffle.
SPARK PLUG Use BPR6ES (NGK) or W20EPR-U (NIPPONDENSO) plug. Gap plug to 0.028 to
0.031 in. (0.7 to 0.8 mm).