SP - 1
SPECIFICATIONS OF AUTO PLOTTER
ARP-17
1. GENERAL
(1) Functions • Calculation/indication of own ship speed relative to a fixed target
• Manual target acquisition, automatic tracking
• Target information:
Distance and bearing from own ship to target
Moving direction and speed
• History presentation
(2) Acquisition and Tracking
• Manual acquisition by trackball and cursor
• Maximum number of targets: 10
• Acquisition range: 0.2 to 32 nm
• Tracking range: 0.1 to 32 nm
(3) Vector • Vector length: 30 sec; 1, 2, 3, 6, 15, 30 min
• Mode: true velocity or relative velocity
(4) History • plotting interval: 30 sec; 1,2,3,6 min
• Number of plotting points: 10 per target
(5) Alarms • Visual and audible alarm against target violating CPA/TCPA limits
• Visual and audible alarm against guard-zone limits (5 targets max.)
• Visual alarm against lost target, target full and system failure
(6) Compatible Radar FR-1700 series, FR-1500 Mark-3 series