ClearOne comm 900 Conference Phone User Manual


 
Appendix — Serial Commands
105
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendix — Serial Commands
104
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
MUTE - Mute
This command selects/reports the setting of mute on a channel.
ARGUMENT DETAILS
Name Type Size Values Units
Channel Channel 1 (all channels only)
Group Group 1 3 (M)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
BINARY FORM DETAILS
COMMAND ID
:12
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Channel><Group><Value>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE MUTE <Channel> <Group> [Value]
NCSEL - Noise Cancellation Select
This command enables/disables or reports the current status of noise cancellation.
ARGUMENT DETAILS
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 3,17 (M,R)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)
BINARY FORM DETAILS
COMMAND ID
:62
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Channel><Group><Value>
TEXT FORM DET
AILS
COMMAND FORM
: DEVICE NCSEL <Channel> <Group> [Value]
MICCAMPRESET - Mic Camera Preset
This command associates a mic with a camera preset for voice tracking.
ARGUMENT DETAILS
Name Type Size Values Units
Channel Channel 1 See Group and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 to Clear
1 - 10
(NULL to Query in Text)
BINARY FORM DETAILS
COMMAND ID
:55
NUMBER OF ARGUMENTS
:1
ARGUMENT FORM
: <Channel><Group><Value>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE MICCAMPRESET <Channel> [Value]
MTRX - Matrix Routing
This command selects/reports the matrix routing of an input to an output.
ARGUMENT DETAILS
Name Type Size Values Units
Source Channel Channel 1 See Group and Channels
Source Group Group 1 3, 7, 17(M, L, R)
Destination Channel Channel 1 Group 3 (M) is only allowed all channels.
All other groups cannot have the all
channel.(See Group And Channels)
Destination Group Group 1 2,16(O,T)
Value Unsigned Integer 4 0 = Cross point off
1 = Cross point on
2 = Toggle
(Null to query in text)
BINARY FORM DETAILS
COMMAND ID
:11
NUMBER OF ARGUMENTS
:2
ARGUMENT FORM
: <Src. Ch.><Src.Gp.><Dest. Ch.><Dest. Gp.><Value>
TEXT FORM DETAILS
COMMAND FORM
: DEVICE MTRX <Src. Ch.> <Src.Gp.> <Dest. Ch.> <Dest. Gp.>
[Value]