1 Press
2 Enter the Relay Number (1-4). Then (
#
)
3 Enter Activation Time (1-300 Seconds). Then (
#
)
Then
1 Press
2 Enter Door Number (1-4). Then (
#
)
3 Enter Relays to be Activated (0000-1111). Then (
#
)
Then
Example:
1 2 3
1 2 3
Assigns Relay “2” as a Shunt Relay
When Activated, the Relay Number “4” will activate for “30” seconds.
When a Resident uses a Valid Code at “Door 1”, Relay “1” and Relay “2” will Activate.
Example:
Example:
1 2 3
1 Press Then
Set Each “Relay Mode” to get the Appropriate Response:
2 Enter the Relay Number (1-4). Then (
#
)
This is the amount of time (in seconds) the relay remains activated. This will define the amount of time a
door cycles (unlocks, then relocks) or how long the CCTV camera remains on after being activated.
Factory Setting: All Relays are set at 10 seconds
EL25 SetUp “Your Settings”
EL25 SetUp “Your Settings”
Set Each Relay's “Activation Time”:
3 Enter Relay Mode (0-5). Then (
#
)
0 = Not Used
1 = Strike -
controls a door/gate by unlocking/opening it.
2 = Shunt -
bypasses the alarm under normal circumstances.
3 = CCTV -
activates system's optional camera.
4 = Alarm -
activates another device (siren).
5 = Control -
controls another device (on/off light).
65
There are
5
different relay modes. The
Relay Mode
determines what the response will be when a valid access
code is entered (open a door, turn on an alarm, turn on a light then turn it off, turn on a CCTV, etc.).
Factory Setting: All Relays are Set at “1 - Strike”
Step 2
Step 3
66
When a
valid
access code is used at an external access control device (Door), the EL25
can be set
to activate
one or more relays.
Factory Settings: Door 1 Activates Relay 1; Door 2 Activates Relay 2;
Door 3 Activates Relay 3; Door 4 Activates Relay 4
Assign “Each” Door Number to One or More Relays:
Step 4
61
Note:
A relay that controls a gate operator
must
be set to activate for
2 seconds
.
0 = Deactivate , 1 = Activate (1st digit=Relay 4, 2nd digit=Relay 3, etc.)
Relay 4 Relay 3 Relay 2 Relay 1
Deact Deact
Activate Activate
Important:
Allthroughepsmust be
performed for
EACH
Door Number
assigned to the unit.
1
3
Important:
Allthroughepsmust be
performed for
EACH
Relay assigned
to the unit.
1
3
Important:
Allthroughepsmust be
performed for
EACH
Relay assigned
to the unit.
1
3