System Operation (Continued)
Note: An asterisk in two or more locations indicates this
fr
equency is in more than one group.
Setting Receiver Frequency Using IntelliScan
Single-r
eceiver systems (either an AEW-R4100 or
an AEW-R5200):
Turn down the AF level of the associated mixer or amplifier.
Make certain that any AEW transmitters are turned
off. (Other
RF-generating devices in the area should be turned
on, if
possible.)
1.
Touch the Mode/Set button once to enter the Menu mode.
(On an AEW-R5200, use Channel 1 to perform the
IntelliScan for both channels.)
2.
Touch the Down arrow once. The display shows “SCAN.”
3.
Hold the Mode/Set button to start the scan. The second line
displays “------” during the scan and then briefly displays
“SCAN OK” when the scan is successfully completed.
4. The display on the receiver then shows “RESET NAMES.”
The receiver remains in this state (system is muted) until one
of the following steps is completed:
a. To accept and use this frequency with the currently
loaded/named pr
eset,
touch the Mode/Set button. The LCD
briefly displays “STORED” and reverts to normal operation.
At this point, the display shows the r
eceiver name/pr
eset
currently loaded. (Note: This frequency is now stored with
the associated named pr
eset and is recalled when that
preset is reloaded.)
b.To accept and use this frequency and store it in the special
“NAME?” location,
hold the Mode/Set button. The LCD
displays “NAME?” on the top line. (Note: Doing this allows
a new frequency to be used without affecting previously
stor
ed pr
eset data. However
, the r
eceiver shows “NAME?”
instead of the pr
eset’s name.)
T
o stor
e this fr
equency along with other settings into one of
the user presets, refer to the instructions on page 15.
IMPORTANT! If one of the above steps (a or b) is not
completed, the r
eceiver will remain in the “RESET NAMES”
state indefinitely (system is muted), and it will
not automatically
back out to normal operating mode.
Multiple-receiver systems:
Turn down the AF level of the associated mixer or amplifier.
Make certain that any AEW transmitters are turned
off. (Other
RF-generating devices in the area should be turned
on, if
possible.)
1. Make certain all the receivers are connected (daisy-chained)
with link cables. The receiver with only a Link In (no Link Out
connection) becomes the Master r
eceiver. (See “Link
connections” on page 9.)
2.
Switch on
all the slave r
eceivers first; switch on the Master
receiver
last. Alternatively, all receivers can be turned on
simultaneously, as when using AC power plug strips
controlled by a single AC switch. (If an AC power or link
connection is interrupted, even briefly,
all receivers must be
turned off and the power-up sequence repeated to assure
complete system control.)
3. Using controls on the Master receiver, follow all the steps
listed for single-receiver systems to assign compatible
frequencies for all receivers by using IntelliScan.
4. The display on the Master shows “RESET NAMES”, and the
display on each slave shows “SCAN” and the new frequency.
The receivers remain in this state (system is muted) until one
of the following steps is completed to accept the new
frequency plan:
a. To accept and use this frequency plan with the currently
loaded/named presets,
touch the Mode/Set button. If a
user preset was previously loaded on the receiver, the LCD
briefly displays “STORED” and reverts to normal operation.
The LCD then displays the previously loaded user preset or
receiver name and the new frequency. (Note: This
frequency is now stored with the associated named preset
and is recalled when that preset is reloaded.) If no user
preset was loaded (i.e., the default settings were in effect),
the LCD shows “NAME?” and the new frequency.
b.To accept and use this frequency
and store it in the special
“NAME?” location,
hold the Mode/Set button. The LCD
displays “NAME?” on the top line. (Note: Doing this allows
a new frequency to be used without affecting previously
stored preset data. However, the receiver shows “NAME?”
instead of the preset’s name.)
To store this frequency along with other settings into one of the
user presets, refer to the instructions on page 15.
Note: These changes af
fect
all linked r
eceivers.
IMPORTANT! If one of the above steps (a or b) is not
completed, the Master and all linked slave r
eceivers will r
emain
in the “RESET NAMES” state indefinitely (system is muted) and
will
not automatically back out to normal operating mode.
Note: A “SCAN ERROR” message may be attributable to one
or mor
e of the following:
• The link connection was broken somewhere in the chain.
• The power to one or more of the linked receivers was turned
off.
• Not enough available frequencies existed for IntelliScan to
assign all receivers a frequency.
If IntelliScan cannot locate enough available fr
equencies, it will
set as many as it can on the linked r
eceivers.
25
Figure R
Group 1
Group 2
Group 3