Symptom Solution
3029
13. Troubleshooting 14.
GMRS-310 Radio Specifications
1. Confirm that batteries are installed.
2. Confirm that your batteries are fresh, and not
discharged.
3. Confirm that the battery polarity is correct.
1. Press monitor and confirm that the speaker sounds.
2. Confirm that the volume has not been turned down.
3. Confirm you are on the same channel and using the
same
Sub-code as the person you are calling.
1. Confirm whether batteries are weak.
2. Change transmit power setting to high (tPr Hi)
3. Move closer to the person you are speaking.
4. Move to a higher elevation.
Confirm BEEP sound has been turned on
.
Confirm that your radio’s sub-code matches the sub-code
of the radio you are calling.
Confirm that your VOX Sensitivity level (SEN) is not set to
lowest number (SEN 1). This level may be too sensitive
for your voice or environment.
Confirm that your VOX Sensitivity level (SEN) is not set to
the highest number (SEN 10). This level may not be
sensitive enough for your voice or environment.
1. Confirm that the VOX delay time is not set to the lowest
number (dLY 025). A Delay setting of 175 to 225 will
generally work well for most users.
Radio does not
power on.
Audio is not
heard over the
speaker.
Audio is not clear.
Poor reception.
BEEP sound is
not heard.
“BUSY” icon shows but
NO reception is heard
.
Continual
transmission in
VOX.
VOX mode does
not activate.
“Broken”
transmissions when
using VOX mode.
RF Impedance 50 Ohm
Frequency Range 462.5625 MHz ~
467.7250MHz
Channel Spacing 12.5KHz
Number of Channels 22
Modulation System FM
(Frequency Modulation)
Maximum RF Output Power
High 0.5W / Low 0.15W
(Conducted High 2W / Low 0.5W)
Operating Temperature -4 F ~ 122 F
(-20 C ~ 50 C)
Dimensions (H x W x D) 6.375” x 2.125” x 1.3125”
(162mm x 54mm x 33mm)
Weight (with batteries) 4.9 oz. (139g)
Battery Requirements AAA size, 4 batteries