ALARM-CAMERA SITE page
Note: Click the [SET] button to save the changed
settings. Otherwise, the changed settings will not be
saved.
Item Descriptions
No.
The numbers of the VIDEO IN connectors
ON/OFF
Set whether to control the encoder by alarm input or
not.
ON
When the camera site alarm is detected, the
following actions will be performed at the same time.
Notification of an alarm occurrence to the
destination set on the ALARM page
Camera is controlled by a preset number
Changing of the bit rate
OFF
The encoder does not detect any alarm from the
camera site. No alarm notification is sent.
The default setting is "ON" for all ports.
VIDEO INPUT CH
The numbers of the VIDEO IN connectors
CAMERA PRESET No. (1 - 16)
When the encoder detects an alarm from a camera
with preset functions connected to the VIDEO IN
connector, the encoder performs the preset control
on the camera. In this case, the preset function
settings for the camera to be controlled should be
performed in advance.
This setting is invalid when a camera without the
preset functions is connected.
There is no default setting.
BIT RATE
When the encoder detects an alarm, the encoder
changes the bit rate of the streaming video data
temporarily. The bit rate of up to 4 streams can be
changed simultaneously when an alarm is detected.
The default setting is "6.14 Mbps (150 ms)" for all
channels.
RESET/TIMER (SEC) 1 - 60, 90, 120, 150, 180, 240,
300 - 3600: 60 SEC INTERVAL
When the alarm is reset, the bit rate returns to the
set value on the VIDEO page and the alarm status is
released.
Select the method of release from the following.