Conditions
• The start times of the following time modes can be specified through PC programming as well as PT
programming.
– Day 1 and 2
– Lunch
– Night
The start and end times of the following break modes can be specified through PC programming only.
– Break 1
– Break 2
– Break 3
Note
that if an end time is programmed for a break, the day mode will start or resume at this time, as shown
previously in "Visualization of Time Schedule for Tenant 1" example. If no end time is programmed, the
break will continue until the start of the next time mode, as shown in Time Table 4 in "Visualization of Time
Schedule for Other Tenants".
• Time Service Switching Mode (Automatic/Manual) Button
Any flexible button can be customized as the Time Service Switching Mode (Automatic/Manual) button.
PC Programming Manual References
4.5 [2-4] Week Table
4.7 [2-5] Holiday Table
4.8 [2-6-1] Numbering Plan—Main—Features—
Time Service (Day / Lunch / Break / Night) Switch
4.11 [2-7-1] Class of Service—COS Settings—Extension Feature
—
Time Service Switch
6.5 [4-1-4] Wired Extension—Flexible Button
→
Type
→ Parameter Selection (for Time Service)
→ Parameter Selection (for Time Service - Automatic/Manual)
→ Optional Parameter (Ringing Tone Type Number) (for Time Service)
6.13 [4-2-3] Portable Station—Flexible Button
→
Type
→ Parameter Selection (for Time Service)
→ Parameter Selection (for Time Service - Automatic/Manual)
→ Optional Parameter (or Ringing Tone Type Number) (for Time Service)
6.17 [4-3] DSS Console
→
Type
→ Parameter Selection (for Time Service)
→ Parameter Selection (for Time Service - Automatic/Manual)
→ Optional Parameter (Ringing Tone Type Number) (for Time Service)
PT Programming Manual References
[101] Time Service Switching Mode
[102] Time Service Starting Time
[514] Time Service Manual Switching
Feature Manual References
3.1.19 COS (Class of Service)
6.1.3 Flexible Buttons
17.1.3 Tenant Service
17.1.6 TRS (Toll Restriction)
Document Version 2008-11 Feature Manual 313
17.1.5 Time Service