RTM-ATCA-7350 Installation and Use (6806800H30F)
Hardware Preparation and Installation Environmental and Power Requirements
18
3. Remove the desiccant bag shipped together with the blade and dispose of it
according to your country’s legislation.
2.3 Environmental and Power Requirements
The following environmental and power requirements are applicable to the board.
2.3.1 Environmental Requirements
The product is thoroughly inspected before shipment. If any damage occurred during
transportation or any items are missing, please contact our customer's service
immediately.
Table 2-1 Environmental Requirements
Requirement Operating Non-Operating
Temperature +5ºC (41ºF) to +40ºC (104ºF) (normal operation)
according to NEBS Standard GR-63-CORE
-5ºC to +55ºC (short term operation) according to
NEBS Standard GR-63-CORE
-40ºC (-40ºF) to +70ºC
(158ºF) (may be further
limited by installed
accessories)
Temp. Change +/- 0.25ºC/min or 15ºC/h (59ºF/h) according to
NEBS Standard GR-63-CORE
+/- 0.25ºC/min or 15ºC/h
(59ºF/h)
Rel. Humidity 5% to 85% non-condensing according to Emerson
Network Power Embedded Computing-internal
environmental requirements
5% to 85% non-condensing
according to Emerson
Network Power Embedded
Computing-internal
environmental
requirements
Altitude <= 4000m
Vibration 1.0g from 5 to 100 Hz and back to 5 Hz at a rate
of 0.1 octave/minute
5-20 Hz @ 0.01 g
2
/Hz
20-200 Hz @ -3.0
dB/octave
Random 5-20 Hz @ 1
m
2
/Sec
3
Random 20-200 Hz @ -3
m/Sec
2
Shock Half-sine, 11 m/Sec, 30mSec/sec
2
Blade level packaging
Half-sine, 6 mSec at 180
m/Sec
2