A SERVICE OF

logo

Equipment Installation Manual,
GEN-X Electronic Flight Bag
1069-2510-01 D.doc
1069-2510-01
Rev D
Page 14 of 27
DU Replacement
1. Attach mount stud body with four screws making sure to select the appropriate set of mounting
holes on the display unit that will be nearest to the aircraft window.
2. Align red dots on DU connector and cable connector. Push together and verify positive lock.
3. Perform operational test of the GEN-X as prescribed in the aircraft maintenance manual.
Battery Replacement
1. Remove RPU according to section “RPU Removal”.
2. Locate and remove the RPU battery cover by removing the two screws holding it to the RPU
housing.
3. Remove battery by pulling on cloth tab.
4. Install new battery observing correct orientation.
5. Reinstall battery cover.
6. Reinstall RPU according to section “RPU ”.
7. Close GEN-X system circuit breakers.
8. Verify battery condition light is off.