Vista 20SE Answering Machine User Manual


 
– 4 –
*
49 SPLIT/DUAL REPORTING [0]
0 = Disable (Backup report only)
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
TO PRIMARY PHONE No. TO PAGING No. * (Secondary)
** A 10-digit code is sent to the pager consisting 6 = All except Open/Close ** Alarms, Open/Close, Troubles
of a 4-digit subscriber number, a 3-digit event code, 7 = All reports ** Alarms, Troubles
and a 3-digit user or zone number. 8 = All reports ** Alarms, Open/Close, Troubles
See Installation Instructions for an explanation 9 = All except Open/Close * * Alarms, Open/Close for
of the 10-digit code. users 5-25 (users 5-16 or
wireless button zones 10-
25), Troubles
* Can only be used if primary reporting format is Ademco Contact ID.
*
50 15 SEC DIALER DELAY (BURG)
[0]
0 = no; 1 = yes; “0” for UL installations
*
51 PERIODIC TEST REPORT
[0]
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days (Enter Test
Code in field
*
64. Reports with Partition 1 subscriber No.)
*
52 TEST REPORT OFFSET
† [2]
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours (Time to 1st
report from programming or downloading).
*
53 SESCOA/RADIONICS SELECT [0]
0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only
reporting). Select 0 for all other formats.
Entry of a number other than one specified will give unpredictable results.
*
56 ZONE ASSIGNMENT/ALARM REPORT CODES —This field is an interactive mode. Fill in the required
data on the worksheet below (and on next page) and follow the programming procedure in the installation
manual.
ZONES ON CONTROL:
See explanation of headings on next page
·
ZONE ZONE ZONE PART'N ALARM RPT CODE INPUT
RESPONSE
DESCRIPTION No. TYPE No. (Hex) TYPE TIME
(Zn) (ZT) (P) (RC) (In) (RT)
Wired Zone 1* 0 1 HW
Wired Zone 2 0 2 HW
Wired Zone 3 0 3 HW
Wired Zone 4 0 4 HW
Wired Zone 5 0 5 HW
Wired Zone 6 0 6 HW
Wired Zone 7 0 7 HW
Wired Zone 8** 0 8 HW
Expansion Module 0 9 0 5
Both
ÑÑ
Supervision
Duress 9 2
Both
ÑÑ
Console Panic (1 & *, or A) 9 5
Both
ÑÑ
Console Panic (3 & #, or C) 9 6
Both
ÑÑ
Console Panic (* & #, or B) 9 9
Both
ÑÑ
*Zone 1 can be used as a 2-wire Fire zone. **Zone 8 can be used as a Glassbreak zone.