– 3 –
*
36 ENTRY DELAY 2 (zone type 02) | | [60] [60]
Part. 1
†
Part. 2
†
00-99 = entry delay 2 time for each
partition; 50 seconds max. for UL installations
*
37 AUDIBLE EXIT WARNING [1] [1]
Part. 1
†
Part. 2
†
0 = no; 1 = yes
*
38 CONFIRMATION OF ARMING DING [0] [0]
Part. 1
†
Part. 2
†
0 = no; 1 = yes (wired keypads and RF); 2 = yes, RF only
*
39 POWER UP IN PREVIOUS STATE
† [1]
0 = no; 1 = yes; “1” for UL installations
DIALER PROGRAMMING (*40–*53)
In fields
*
40,
*
41,
*
42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '*';
#+12 for '#'; #+13 for a pause.
*
40 PABX ACCESS CODE | | | | |
Enter 6 digits. If fewer than 6 digits are entered, exit by
pressing
*
(and press 41, if entering next field). To clear entries
from field, press
*
40
*
.
*
41 PRIMARY PHONE No. | | | | | | | | | | | | | | |
Enter up to 16 digits; Do not fill unused spaces. If fewer than 16
digits entered, exit by pressing
*
(and press 42, if entering next
field). To clear entries from field, press
*
41
*
.
*
42 SECONDARY PHONE No. | | | | | | | | | | | | | | |
Enter up to 16 digits; Do not fill unused spaces. If fewer than 16
digits entered, exit by pressing
*
(and press 43, if entering next
field). To clear entries from field, press
*
42
*
.
*
43 PRIMARY SUBS ACCT # (Part. 1) | | |
*
44 SECONDARY SUBS ACCT # (Part. 1) | | |
*
45 PRIMARY SUBS ACCT # (Part. 2) | | |
*
46 SECONDARY SUBS ACCT # (Part. 2) | | |
NOTE: If using the paging feature, do not enter a
leading 0 in the subscriber account number, and do
not use digits A-F anywhere in the number. Some
paging systems provide voice mail capability, which
is activated by a leading 0 in the message.
For fields *43 - *46:
Enter 0–9; #+11 for B; #+12 for C; #+13
for D; #+14 for E; [#+15 for F]. Enter
*
as
4th digit, if 3+1 dialer reporting is to be
used. If only 3 digits used, exit by pressing
*
(and press next field).
To clear entries from field, press
*
43
*
,
*
44
*
,
*
45
*
, or
*
46
*
.Examples:
For Acct. 1234, enter: 1 | 2 | 3 | 4
For Acct. B234, enter: #+11| 2 | 3 | 4
For Acct. 123, enter: 1 | 2 | 3 | *
*
47 PHONE SYSTEM SELECT
†
[1]
If Cent. Sta.
IS NOT
on a WATS line: 0 = Pulse Dial; 1 = Tone
Dial; if Cent. Sta.
IS
on
a WATS line: 2 = Pulse Dial ; 3 = Tone
Dial.
*
48 REPORT FORMAT [7] [0]
Primary Secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
†
Entry of a number other than one specified will give unpredictable results.