Vista 20SE Answering Machine User Manual


 
– 2 –
Local programming requires the use of a 2-line Alpha keypad connected to
partition 1 keypad terminals on the control.
NOTE: For UL installations, the system may be configured as a single partition only.
Field Function Programmed Values [ ] = Default Value
SYSTEM SETUP (*20–*29)
*
20 INSTALLER CODE | | | [4 1 1 2]
Enter 4 digits, 0–9
*
21 QUICK ARM ENABLE [0]
Part. 1
Part.2
0 = no; 1 = yes
*
22 RF SYSTEM [0]
0 = none; 1 = 5800 (5881/5882)
*
23 FORCED BYPASS [0] [0]
Part. 1
Part. 2
0 = none; 1 = bypass open zones
“0”. for UL installations.
*
24 RF HOUSE ID CODE | [0][0]
00 = disable all wireless keypad usage; 01–31 = using 5827
keypad; Partition 2 RF House ID = Partition 1 House ID +1
*
25 WIRED ZONE EXPANSION
[0]
0 = none; 1 = 4219; 2 = 4229; 3 = 4204
*
26 CHIME BY ZONE
[0]
0 = no; 1 = yes (program zones to chime on zone list 3)
*
27
X–10 HOUSE CODE
[0]
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 =
J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P
*
28 PHONE MODULE ACCESS CODE | [00]
(Partition 1 only) 1st digit: enter 1–9; 2nd digit: enter # + 11 for "
*
", or # + 12 for "#". Entering 0 for either digit disables code.
*
29 OUTPUT TO LONG RANGE RADIO [0]
0 = disable; enable = Trouble code 1–9, B (# +11), C (# + 12), D
(# + 13), E (# + 14), or F (# + 15). The 2nd digit of Trouble Dialer
Report is automatically entered from field
*
60. “0” for UL
installations.
ZONE SOUNDS AND TIMING (*31–*39)
*
31 SINGLE ALARM SOUNDING/ZONE
[0]
1 = yes; 0 = no; “0” for UL installations.
*
32 FIRE SOUNDER TIMEOUT
[0]
0 = timeout; 1 = no timeout
*
33 ALARM BELL TIMEOUT
[1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min; “1” (4 min.)
minimum for UL.
*
34 EXIT DELAY | | [70] [70]
Part. 1
Part. 2
00-99 = exit delay time for each partition
*
35 ENTRY DELAY 1 (zone type 01) | | [30] [30]
Part. 1
Part. 2
00-99 = entry delay 1 time for each
partition; 20 seconds max. for UL installations
Entry of a number other than one specified will give unpredictable results.