ClearScan™
ClearScan™ per forms a fre quency scan of the fac tory-defined
and any set-up user-programmable groups in or der to find the
group with the high est num ber of clear re ceive chan nels. Af ter
about 20-30 sec onds, the group with the high est num ber of
clear re ceive chan nels will be dis played. The next best group
and so forth may be ac cessed with the [DOWN] and [UP]
arrow but tons.
Press and hold [MENU] + [SET] for three seconds to en -
ter ClearScan™. The base sta tion will now start search ing
all groups for the ones with the great est num ber of re -
ceiver chan nels clear of in ter fer ence.
ClearScan™ will dis play the group that has the most in -
ter fer ence free re ceive chan nels. These clear chan nels are
dis played on the right half of the screen. Press [SET] to
place the base sta tion on this group and re turn to the op er -
at ing screen. The first four re ceive chan nels dis played
will be the ones set for the group. The [UP] / [DOWN]
but tons may be used to se lect the next best group and so
forth.
7-9
ClearScan
TM
Group 03A
OK?=[SET]
Next
01 05
02 06
03
04 08
Group 04b 01 05
OK?=[SET]
Prev
Next
06
03
04 08
[DOWN]
[SET]
Group 04b
T1T1
44
R1R1
On
On
22
33
T1T1
22
Ch A
Ch B
TA A
no tx
END
ClearScan™